SDC Security Door Controls 928 Series Integrated Digital Keypad, 480 PIN Codes
![]() |
Product Overview
The SDC 928 EntryCheckTM is a stand alone digital keypad designed to control access of a single entry point for facilities with up to 480 users. Each user is assigned a personal identification number (PIN). Keypad entry of a valid one to six digit code activates one or both of the output relays which releases an electric door lock.
• Keypad programmable
• 480 user codes
• 1 to 6 digit user codes
• 4 independent outputs
• 4 independent timers
• 2 Form C relay contacts
• 2 solid state open collector outputs
• Program entry codes to activate one or two relays
• Disable input
• Door sense input
• Request-to-exit/enter input
• Keypad tamper lockout
• Timed anti-passback
• Anti-tailgate
• Two LED status indicators
• Tactile key feel
• Audible code entry verification
• 12 or 24V, AC or DC operation
Specifications
Dimensions: 3”W x 5”H x 3”D
Voltage: 12/24 VAC/DC
Current: 10mA typical, 150mA maximum
Outputs: Relay 1 - Form “C”, 5 Amps @ 24VDC
Relay 2 - From “C”, 1 Amps @ 24VDC
Outputs 3 & 4 - Switch to common,
100mA @ 30VDC
Temperature: -20°F to + 130°F (-30°C to + 54°C)
Humidity: 5% to 95% non-condensing
Outputs
The EntryCheckTM features four independent outputs with four independent timers. Outputs #1 and #2 are Form “C” relay contacts. Outputs #3 and #4 are solid-state open collector outputs, short to common, which may be used to signal forced entry, door ajar, lockout, shunt alarms, request to exit or keypad active conditions.
Programmable Operating Features
• System reset
• Entry code length, 1 to 6 digits
• Adding a new PIN
• Erasing a single PIN
• Erasing all PINs
• Changing the master programming code
• On-time for each of the four outputs
• Beep sounds on key presses
• Beep sound during each of the four outputs activation time
• Keypad lockout after specified number of incorrect PIN attempts, from 2 to 7
• Anti-passback time period from 1 to 4 minutes or no anti-passback protection
• Anti-tailgate
• Alarm shunt output
• Forced entry output
• Door ajar output
• Door sense/inhibit input
• Keypad lockout output
• Keypad active output
Programming Options
The 928 EntryCheckTM includes a Door Sense/Inhibit Input
feature. When programmed for "Door Sense", a door
position switch wired into the input and detects a "forced
entry" or "door ajar" condition. When programmed for "Inhibit
Input", a maintained switch or automatic timer wired into a
the input will disable the activation of the main relay.
The EntryCheckTM also has a request-to-exit input for
connection to an exit switch and/or fire access key switch for
fire/emergency access. When access is granted, the shunt
option is activated shunting alarm contacts on the door or
gate. This prevents triggering of an alarm during
authorized access.
| Format | N/A |
|---|---|
| Manufacturer | SDC Security |
| Manufacturer Warranty | 2 Year |
| Operation | PIN Only |
| Power Requirements | 24V/12V AC/DC |
| Maglocks.com Rating | Better |